Synopsis

A Noninvasive Quantum Thermometer

Physics 14, s35
A quantum dot can measure ultracold temperatures without the need for direct electrical connections to the outside world.
Mario Beauregard/stock.adobe.com

Accurate measurements of temperature are essential for understanding the behavior of ultracold circuits, such as the ones used in quantum computers. While a number of “electron thermometers” exist for this purpose, they all require a direct electrical connection to the circuit, something that can interfere with the circuit’s electronic behavior. Now, researchers have circumvented that requirement with a quantum-dot thermometer that can accurately measure temperatures down to 1 K without a direct electrical connection [1].

As a circuit’s temperature changes, so does the range of energies that electrons can occupy in the circuit. This distribution is observable in a component of a quantum dot’s capacitance known as the “tunneling capacitance.” Previous quantum dot thermometers worked by measuring the current through the dot or by direct charge sensing. Joshua Chawner of Lancaster University in the UK and colleagues instead use an indirect approach that leverages this tunneling capacitance.

In their experiments, the quantum dot was close to, but not directly contacting, one gate of a transistor in an electric circuit. A radio-frequency signal was sent through the circuit to this gate. They then measured the returned signal’s phase, which shifted as the dots’ tunneling capacitance changed.

Testing the thermometer in a cryogenic refrigerator—with a second thermometer as a check—the team demonstrated that their setup works for temperatures down to about 1 K. Below that, the readouts from the two thermometers diverged but stayed within one standard deviation of each other. The team is now working on improving the quantum dot thermometer’s accuracy below 1 K, which they say will require redesigning the quantum dot to alter its tunneling capacitance.

–Christopher Crockett

Christopher Crockett is a freelance writer based in Arlington, Virginia.

References

  1. J. Chawner et al., “Nongalvanic calibration and operation of a quantum dot thermometer,” Phys. Rev. Applied 15, 034044 (2021).

Subject Areas

Semiconductor PhysicsElectronics

Related Articles

Molecular-Orbital Electron Sources
Atomic and Molecular Physics

Molecular-Orbital Electron Sources

The molecular orbitals of a single C60 molecule on a tungsten tip can be used to shape the emission pattern of electrons. Read More »

A Solid Observation of Strong Kerr Nonlinearity
Condensed Matter Physics

A Solid Observation of Strong Kerr Nonlinearity

Researchers have demonstrated that a solid can exhibit an enhanced nonlinear optical phenomenon usually seen only in cold atomic gases. Read More »

Quantum Thermal Transistor Amplifies Heat Currents
Electronics

Quantum Thermal Transistor Amplifies Heat Currents

A three-qubit transistor design offers a way to manipulate the system’s heat flow by hitting one of the qubits with a laser.   Read More »

More Articles