Synopsis

Going with the Flow

Physics 6, s143
Locally heating blood with ultrasound lets researchers track its motion with laser probes even when the fluid is moving slowly.
L. Wang et al., Phys. Rev. Lett. (2013)

Measuring local blood flow inside living creatures provides insight into both normal functions and diseases. Ultrasound can probe deep within tissues by using the Doppler shift of the sound waves’ frequency to detect the motion of blood cells. But this effect is unmeasurable for blood moving slower than about ten millimeters per second. In Physical Review Letters, Lidai Wang and his colleagues at Washington University, Missouri, demonstrate that ultrasonic waves can instead be used to heat a small volume of blood, thereby “tagging” it. The motion of this tagged blood is then tracked by a light-based technique. In a test setup, they measured speeds as low as a quarter of a millimeter per second.

To track the motion of the tagged blood, the researchers exploited the photoacoustic effect, in which absorption of an infrared light pulse locally expands a material, generating sound waves. Because the amplitude of these sound waves varies with the starting temperature of the blood, laser pulses repeated ten times a second showed directly how the ultrasonically heated region moved. Comparing subsequent “snapshots” of the sound waves, which were captured with an array of detectors, let the team follow the flow in a 1.5-mm tube of cow’s blood, including its faster speed at the center of the tube.

Unlike ultrasound, the near-infrared light interacts more strongly with blood than with tissue, but can’t be focused deeper than a millimeter. But because their technique gets its resolution from the sound imaging, the researchers were able to measure blood speeds in their test sample even when the light had to first pass through a 5-mm-thick piece of chicken breast tissue. – Don Monroe


Subject Areas

Medical Physics

Related Articles

One Ring to Measure Blood-Glucose Level
Metamaterials

One Ring to Measure Blood-Glucose Level

A proposed ring-shaped device could measure the concentration of glucose in a person’s blood to an accuracy sufficient to make it clinically useful. Read More »

“Fictitious” Magnetic Fields for Atomic Magnetometers
Medical Physics

“Fictitious” Magnetic Fields for Atomic Magnetometers

Researchers have achieved dual-axis magnetic-field detection using an atomic magnetometer architecture with only optical instruments. Read More »

Predicting Hemorrhagic Stroke
Medical Physics

Predicting Hemorrhagic Stroke

Patient-specific modeling could help clinicians determine whether an individual’s brain aneurysm is at risk of bursting. Read More »

More Articles